§ 15.40.348. Heating systems and facilities.  


Latest version.
  • A.

    When the dwelling or dwelling unit is heated by a central heating system:

    1.

    The central heating unit shall be in good working condition.

    2.

    Every heat, duct, steam and hot water pipe shall be free of leaks and functions so that adequate heat is delivered where intended.

    3.

    Every seal between the sections of a hot air furnace shall be in good repair.

    B.

    When the dwelling or dwelling unit is heated by space heaters:

    1.

    Every space heater burning solid, liquid or gaseous fuels shall be properly vented to a chimney or gas vent leading to outdoor space.

    2.

    Every coal-burning space heater shall have a fire resistant panel beneath it.

    3.

    Every space heater located close to a wall shall be equipped with insulation sufficient to prevent overheating of the wall.

    4.

    Every space heater smoke pipe shall be equipped with guards made of metal or other nonflammable material at the point where the pipe goes through a wall, ceiling or partition.

    C.

    There shall be no portable heaters burning solid, liquid or gaseous fuels.

    D.

    Every smoke pipe and every chimney shall be adequately supported, reasonably clean and maintained in such condition that there will be no leakage or backing up of noxious gases.

    E.

    All heating facilities shall comply with all applicable provisions of this chapter relating to heating and heating facilities, and the village building code.

(Ord. 1977-14 § 11-5, 1977)